Tuesday, July 14, 2009

No-hassle SQL connection strings

Most applications working with a database handle the connection string in one of two ways: Hard-coding the full string or doing some amount of string concatenation. A typical concatenation method looks something like this:

public string OldMethod(string server, string database,
                        string username, string password)
{
    string connectionString = "Data Source=" + server + ";";
    connectionString += "Initial Catalog=" + database + ";";
    connectionString += "User ID=" + username + ";";
    connectionString += "Password=" + password;
 
    return connectionString;
}

I admit this is fairly simple code. The only potential issues might be a property name typo or a misplaced (or missing) semicolon. But why hassle with even that much when the dotNet Framework has the same functionality built into the SqlConnectionStringBuilder class? With a reference to System.Data.SqlClient, the above method can be replaced with:

public string NewMethod(string server, string database,
                        string username, string password)
{
    SqlConnectionStringBuilder connBuilder 
        = new SqlConnectionStringBuilder();
 
    connBuilder.UserID = username;
    connBuilder.Password = password;
    connBuilder.InitialCatalog = database;
    connBuilder.DataSource = server;
 
    return connBuilder.ToString();
}

In either case, the output is identical:

Data Source=myServer;Initial Catalog=myDatabase;User ID=myUser;Password=myPassword

Note: If you are working with a database other than MSSQL, there are several other classes derived from the common DbConnectionStringBuilder base class, such as OdbcConnectionStringBuilder and OracleConnectionStringBuilder.

Monday, July 6, 2009

Quickly escape strings in xml

If you spend much time working with xml, you will find yourself needing to escape strings. Replacing '<' with '&lt;' for example. Usually the code written to do so looks something like this:

escapedItem = itemToEscape.Replace("&", "&amp;")
                          .Replace("<", "&lt;")
                          .Replace(">", "&gt;")
                          .Replace("'", "&apos;")
                          .Replace("\"", "&quot;");

Though this technically works, there is an easier way built right in to the .Net framework. If we reference System.Security we can replace the above code with

escapedItem = SecurityElement.Escape(itemToEscape);

In both cases, the string

If (x < 2) & (y > 3), where \"x\" isn't...

is replaced with

If (x &lt; 2) &amp; (y &gt; 3), where &quot;x&quot; isn&apos;t...

Tuesday, May 19, 2009

An easier way to manage CruiseControl.Net projects

In a much older post I showed a quick way to remove duplication in a CruiseControl.Net (CCNet) config file. Since then, CCNet has added a Configuration Preprocessor to not only simplify this process, but also split the ccnet.config into multiple files - one per project.

To start with, we need to modify ccnet.config to specify the correct xml namespace:

<cruisecontrol xmlns:cb="urn:ccnet.config.builder">

Now we move an existing project from ccnet.config into a separate file. Note this new file starts with 'project' as the root node, and must also have the correct xml namespace.

<project xmlns:cb="urn:ccnet.config.builder">
    <name>My Test Project</name>
    <triggers>
        <intervalTrigger seconds="60" />
    </triggers>
    <sourcecontrol type="svn">
        <executable>svn.exe</executable>
        <trunkUrl>svn://MySourceServer/myAppPath</trunkUrl>
        <workingDirectory>C:\CCNetProjects\MyTestProject</workingDirectory>
        <username>svnUser</username>
        <password>svnPassword</password>
        <autoGetSource>true</autoGetSource>
    </sourcecontrol>
    <tasks>
        <msbuild>
            <logger>c:\ThoughtWorks.CruiseControl.MSBuild.dll</logger>
            <projectFile>MyTestProject.sln</projectFile>
            <buildArgs>/noconsolelogger</buildArgs>
            <targets>Build</targets>
            <workingDirectory>D:\CCNetProjects\MyTestProject</workingDirectory>
        </msbuild>
    </tasks>
    <publishers>
        <statistics/>
        <xmllogger/>
        <artifactcleanup cleanUpMethod="KeepLastXBuilds" cleanUpValue="25" />
    </publishers>
</project>

In the main ccnet.config, our project information can be replaced with an include that points to our new project config:

<cb:include href="C:\MyTestApp.ccnet.config" />

Instead of one massive config file, we now split it by project. This makes adding, removing, or modifying projects much easier. As an added bonus, CCNet monitors the project-specific config files and reloads them if anything changes.

I mentioned that we can also use the preprocessor to reduce duplication. In the project config above, note the Subversion username and password nodes:

<username>svnUser</username>
<password>svnPassword</password>

If we define these values in each individual config, changing them requires a find/replace across multiple files. What we want to do is define them once in the main ccnet.config and then include them in our project configs. To do this, we start by adding the following to ccnet.config

<cb:define name="svnCredentials">
    <username>svnUser</username>
    <password>svnPasswrod</password>
</cb:define>

In our project config we can replace the two credential nodes with a single reference to 'svnCredentials'. If we ever change the account our buildserver uses to pull code, we only need to change the credentials once.

<sourcecontrol type="svn">
    <executable>svn.exe</executable>
    <trunkUrl>svn://MySourceServer/myAppPath</trunkUrl>
    <workingDirectory>C:\CCNetProjects\MyTestProject</workingDirectory>
    <cb:svnCredentials/>
    <autoGetSource>true</autoGetSource>
</sourcecontrol>

Monday, April 6, 2009

Mmc load failure

After running our legacy installer we ran into yet another problem - the Computer Management administrative app quit working. Attempting to start it gave an error stating:

MMC cannot open the file C:\WINDOWS\system32\compmgmt.msc.

This may be because the file does not exist, is not an MMC console, or was created by a later version of MMC. This may also be because you do not have sufficient access rights to the file.


To debug this particular issue, we turn to Process Monitor. When we start up the app, the first item shown is a filter dialog. For this session, we need to add mmc.exe to the list of processes to monitor.


Though it's useful to see all activity for a given process, we are generally focused on errors. To make this easier, we want to highlight any log entries that do not have a Result of 'SUCCESS'


Once we have Process Monitor configured and running, we can start the Computer Management tool. The logs will quickly fill up with registry and filesystem events, many of which will be highlighted


In the above screenshot, notice the registry ReadOpenKey failures for various items under "HKCR\CLSID\{2933BF90-7B36-11d2-B20E-00C04F983E60}". I don't know off hand what those sub-items specify, but without them I do know you will be unable to load the associated COM object. To determine what dll was at fault, we went to another computer and looked for that section in the registry.


Note above the default value of "C:\WINDOWS\system32\msxml3.dll." For whatever reason, our installer was unregistering this system dll - definitely not a good thing. Fixing the problem on the broken box was as simple as running regsvr32 on msxml3.dll.

Friday, March 27, 2009

Runtime profiling a COM registration failure

As a continuation of my last post, we had another registration error with the same legacy installer. This time the problem was with mssoap30.dll. Loading the dll in Dependency Walker revealed a single error with dwmapi.dll.


With a bit of web searching we found that dwmapi.dll is only present on Vista and later machines. Since we weren't using that dll directly it shouldn't be the cause of our issue on Windows XP.

At this point it would appear we have all necessary dlls and that our problem must be elsewhere. The documentation on Dependency Walker, however, provides some useful information:

When a module is first opened by Dependency Walker, it is immediately scanned for all implicit, delay-load, and forwarded dependencies. Once all the modules have been scanned, the results are displayed. In addition to these known dependencies, modules are free to load other modules at run-time without any prior warning to the operating system. These types of dependencies are known as dynamic or explicit dependencies. There is really no way to detect dynamic dependencies without actually running the application and watching it to see what modules it loads at run-time.

Version 2.0 and later of Dependency Walker provides a Profile option from the menu. If you have a dll loaded, however, the item is disabled - you have to load an executable first.


For this to work, you need to load regsvr32.exe, which will enable the menu items. Once done, select Profile > Start Profiling to bring up the Profile Module dialog. The only necessary change is to add the dll being registered to the "Program arguments" setting.


Press OK and wait for the application to run. Eventually you will see the usual registration error message box, which you can simply click to continue. Once finished, scrolling through the results shows a couple errors for mssoapr3.dll.


The first error states that the file path specified can't be found. Double-clicking the error shows that it is looking for the dll under "c:\temp\1033". The second states that it cannot find the file - this time in the same folder as the dll we tried to register. So it seems either location is valid for this particular dependency.

Once we add mssoapr3.dll to the same folder, mssoap30.dll registers without issue.

Tuesday, March 24, 2009

COM dll registration failure

Every shop has at least one legacy piece of software they have to support. Written in VB6. With lots of copy/paste code and sections that may or may not still be active. By a developer long since gone from the company. It's bad enough to have to deal with the code itself, but try and rebuild the equally-convoluted installer and you might just go mad.

Our problem wasn't in rebuilding the installer, per-se, but in getting it to run successfully afterward. One issue we ran into were COM dlls that failed to self register.


When we attempted to run regsvr32 on this particular dll, we were given an error dialog stating:

LoadLibrary("C:\WINDOWS\system32\pcmcom.dll") failed - The specified module could not be found.

This particular issue is often due to a missing dependency. To verify this we opened up Dependency Walker and loaded pcmcom.dll. In the screenshot below, you can see the yellow question mark symbol next to pcm.dll - our missing dependency. Once we found pcm.dll and its dependencies, pcmcom.dll registered without issue.

Friday, March 20, 2009

Subversion revision corruption

Say that three times fast...

We ran into an interesting issue earlier this week with Subversion. When attempting to perform any sort of operation on one of our repositories, the operation failed with an error stating "Final line in revision file longer than 64 characters svn: PROPFIND of '/svn/myRepository/myProject'."

When a checkin is made to Subversion, the file differences are compressed and saved to disk under \myRepository\db\revs\. Each checkin will be in a separate file named to match the revision number. Thus revision 1200 is saved to a file named "1200" (no extension.) If you open one of these files in a text editor, you will mostly see unreadable binary. One noticeable feature in all of the files is a pair of numbers on the last line - "10550 10745" perhaps. In our particular case the final revision contained two additional lines following the number pair:

100.1.1.10 - myUser [16/Mar/2009:10:12:06 -0500] "PROPFIND /svn/myRepository/!svn/bln/2914 HTTP/1.1" 207 464
100.1.1.10 - myUser [16/Mar/2009:10:12:06 -0500] "PROPFIND /svn/myRepository/myProject HTTP/1.1" 207 714


These lines are normally found in the Apache log file - not a good sign. A web search verified that it is a known issue with no resolution. The good news is that the page links to a Python script that attempts to repair corrupt revisions. (More information on using the script can be found here.)

The bad news? The script didn't entirely work for us - some of the header info on the compressed diffs had been lost. Fortunately, it did remove the Apache log info from the tail of the file, so other developers could again work. The only section now corrupt was the project where the revision error occurred. This project started returning an error stating "Checksum mismatch while reading representation."

With the issue isolated, the next step was to remove the corrupt revision. Unfortunately, the only way to do that in Subversion is to export the good revisions and then build a new repository using those exports. Say revision 120 is bad and we have a total of 150 revisions. We start by dumping revisions 1 through 119 to a file:

svnadmin dump c:\myRepository\ -r1:119 > c:\DumpPart1.dmp

We then need an incremental dump for changes 121 through 150:

svnadmin dump c:\myRepository\ -r121:150 -- incremental > c:\DumpPart2.dmp

Rename the folder "myRepository" to something else as a quick backup, then create a new database:

svnadmin create c:\myRepository

Copy any config files from the backup repository (such as user accounts) then load the dumps into the new database:

svnadmin load c:\myRepository < c:\DumpPart1.dmp
svnadmin load c:\myRepository < c:\DumpPart2.dmp


One item of note: Loading a Subversion dump effectively creates new checkins for each item in that dump. All items in the second dump above will have a revision number one lower than previously - checkin 121 in the old database becomes checkin 120 in the new database. Though I've not seen it, some developers may receive an error if their local code contains a newer revision number than the database. As I ran a few test checkins after creating the new database, this wasn't a problem.